Level control panels for overflowing pool compensation basin. Control by 5 probes (included) and 1 solenoid valve 24VAC (not included). Start/stop signal for sewage treatment plant.
Filling control for overflow swimming pool with 24 VAC solenoid valve compensation tank, with start and stop contact for filling pump. Control by 5 level probes included. Supply voltage 230 VAC.
| SPECIFICATIONS | VALORES |
| Feeding | 230VAC, -20%…+30%, 50-60Hz |
| Voltage at valve start and stop probes (TH-FILL) | 24 VAC 50 Hz |
| Voltage at pump start/stop sensors (UH1) | 12 VAC 50 Hz |
| Current in the probes | 1.2 mA max. in short circuit |
| Sensitivity of the valve start/stop sensor (TH-FILL) | Adjustable from 60 to 200 kΩ |
| Sensitivity of pump start/stop sensor (UH1) | Adjustable from 3 to 60 kΩ |
| Solenoid valve output | 24 VAC / 16 VA max. |
| Valve opening/closing delay time | Adjustable from 5 to 40 seconds |
| Max. terminal cross-section | 4mm2 (power) / 4mm2 (valve) / 2.5mm2 (control) |
| Output contact | Valve: Potential free, 5 A / 250 VAC max. Pump: 2 A - 250 VAC max. |
| Cable glands (Network/Control) | 2xM20/4xM16 |
| Working temperature | -10 +55ºC |
| Protection | IP65 |
| Measurements (H x W x D) | 330 x 215 x 15 mm |
| Net weight | 2,6 kg (without probes) 3 kg (including probes) |
| CODES | REFERENCES |
| 10002750 | ECO-FILL-2 |
PRODUCTS RELATED
CONTACT WITH US